SITRANS FC430 Mass Flow Meter

Building on a strong tradition - now with NTEP approval for custody transfer


Building on a strong tradition of innovative thinking, Siemens has designed the next generation of coriolis flowmeters for excellence in performance, safety and user-friendliness: the SITRANS FC430.

The digitally based SITRANS FC430 flowmeter features market-leading compactness, very high accuracy of 0.1%, low pressure loss, extremely stable zero point and best-in class data update with 100 Hz high-speed signal transfer.

Unique support tools provide direct access to all operational and functional data, certificates and audit trails. The SITRANS FC430 is amongst the first Coriolis flowmeters to offer SIL 3 certification on the system, meeting the highest standards of safety and reliability.

With the SITRANS FC430, process optimization has never been easier - or more innovative.

The  complete flowmeter system SITRANS FC430 can be ordered for standard, hygienic or NAMUR service. All versions can be ordered for CT service, according to OIML R117 (Liquids other than water).

All compact variants can be validated and configured for SIL2 or SIL3 operation as standard. SIL3 operation requires two flowmeters in series and monitored by a SIL rated control system.

The flowmeter is based on the latest developments within digital signal processing technology – engineered for high measuring performance:

  • Fast response to  rapid changes in flow

  • Fast dosing applications

  • High immunity against process noise

  • High turndown ratio of flowrates

  • Suitable for liquid and gas service

  • Easy to install, commission and maintain

FC430 is available as standard with 4-20 mA analog output with HART 7.2. Additional input/output functions can be freely configured for analog, pulse, frequency, relay or status.

The transmitter comes with a  user configurable graphical display and new SensorFlash® technology, a micro SD card for configuration backup, firmware update and data storage.




DN15 (½")
DN25 (1")
DN50 (2")
DN80 (3")





Flow range (water @ 1 bar pressure loss)

DN15: 3700 kg/h (8157 lb/h)
DN25: 11500 kg/h (25353 lb/h)
DN50: 52000 kg/h (114640 lb/h)
DN80: 136000 kg/h (300000 lb/h)


Compact or remote configuration with selection of twelve languages including Chinese and Russian


Full graphical display, 240 x 160 pixels

Power Supply

24 to 90 V DC, 100 to 240 V AC


4,6 - 50 kg



Wetted parts: 316L stainless steel
Enclosure: 304 stainless steel


Aluminium with corrosion-resistant coating

Enclosure Rating (IP)

IP 67

Pressure ratings

Measuring tubes

Stainless steel: 100 bar (1450 psi)

Sensor enclosure

20 bar (DN15, DN25)
17 bar (DN50, DN80)

Sensor enclosure burst pressure

>160 bar (all sizes)

Temperature ratings

Process medium

-50 to 200 °C (-58 to 392 °F)


-40 to 60 °C (-40 to 140 °F)

Process connections


EN1092-1 B1, EN1092-1 D, ANSI / ASME B16.5, JIS B 2220,

Pipe threads

ASME B1.20 (NPT), ISO228-1 G (BSPP), VCO Quick-connect

Hygienic threads

DIN11851, DIN11864-1, ISO2853, SMS 1145

Hygienic clamps

DIN11864-3A, DIN32676, ISO2852


Pressure equipment




Custody transfer SITRANS FC430


Operational safety (compact system only)

SIL2 (Sensor)
SIL3 (Transmitter and redundant system)


Complying with NE132, NE41


Up to 4 channels combining analog, relay or digital outputs and binary input


HART 7.2

EMC performance

EN 61326-3-2

Mechanical load

18 to 1000 Hz random, 3.17 G rms, in all directions


  • Direct integration - into DCS automation systems via HART 7.2 or as standalone solution

  • Safety integration – approved to SIL3 at design level for compact systems (see note)

  • Space-saving – remote sensor installation provides opportunity for optimal transmitter location

  • SensorFlash® – comprehensive removable memory functions (micro SD card)
    - Calibration certificates
    - Pressure and material test certificates (as ordered)
    - Non-volatile memory backup of operational data
    - Transfer of user configuration to other flowmeters

  • NAMUR (NE132) – sensor dimensions, transmitter functions, output setups, error handling

  • Hygiene approved – EHEDG and 3A approved hygienic sensor. External cleanability, couplings