SITRANS FC410

SITRANS FC410 Coriolis flow meter: large-scale performance in a small scale package

Description

The SITRANS FC410 flowmeter solution is the lightest and most compact Coriolis system worldwide – you can reduce skid size, fit multiple units into the tightest areas, simplify installation into both new and existing applications, and minimize costs. The fully digital generation of compact flowmeters is tailored for direct integration into machine control systems.


FC410 Installation Video

Detail

Specifications

Sizes

DN15 (½")
DN25 (1")
DN50 (2")
DN80 (3")

Accuracy

±0.10%

Repeatability

±0.05%

Flow range (water @ 1 bar pressure loss)

DN15: 3700 kg/h (8157 lb/h)
DN25: 11500 kg/h (25353 lb/h)
DN50: 52000 kg/h (114640 lb/h)
DN80: 136000 kg/h (300000 lb/h)

Power Supply

24 V DC ±20%

Weight

4,6 - 50 kg

Materials

Sensor:

Wetted parts: 316L stainless steel; Hastelloy C22
Enclosure: 304 stainless steel

Transmitter:

Aluminium with corrosion-resistant coating

Enclosure Rating (IP)

IP 67

Pressure ratings

Measuring tubes

Stainless steel: 100 bar (1450 psi)
Hastelloy: 160 bar (2321 psi)

Sensor enclosure

20 bar (DN15, DN25)
17 bar (DN50, DN80)

Sensor enclosure burst pressure

>160 bar (all sizes)

Temperature ratings

Process medium

-50 to 200 °C (-58 to 392 °F)

Ambient

-40 to 60 °C (-40 to 140 °F)

Process connections

Flanges

EN1092-1 B1, EN1092-1 D, ANSI / ASME B16.5, JIS B 2220, DIN11864-2A

Pipe threads

ASME B1.20 (NPT), ISO228-1 G (BSPP), VCO Quick-connect

Hygienic threads

DIN11851, DIN11864-1, ISO2853, SMS 1145

Hygienic clamps

DIN11864-3A, DIN32676, ISO2852

Approvals

Pressure equipment

PED, CRN

Hygienic

3A, EHEDG

NAMUR

Complying with NE132

Process values

Mass flow
Volume flow

Density
Process temperature

Totalizer

1 totalizer for net mass flow

Communication

Modbus RTU TS-485 2-wire communication

EMC performance

EN 61326-3-2

Mechanical load

18 to 1000 Hz random, 3.17 G rms, in all directions


Benefits

  • Space-saving – compact sensor and built-in transmitter allow for more efficient skid and plant layout

  • Direct integration – into new or existing control systems with multidrop-addressable Modbus RTU RS485 communication protocol and fully configurable byte order to support all PLC types

  • Easy installation – with standard connections and streamlined wiring

  • High accuracy – ±0.1% achieved at up to 160 bars and 200 °C

  • Hygienic – EHEDG and 3A approved with a smooth surface for easy cleaning and minimal abstraction of flow

  • Flexible – available from DN15 to DN80 to ensure a broad application fit

  • Dedicated performance - delivers true multi-parameter measurements (e.g. mass flow, volume flow, density and temperature)

  • High speed – 10 m/s signal update for reliable data transfer and up to 115,2 kBit/s RS485 data rates for multiple instruments


Did this information help you?